A member of the Omnia Group

Viperdet Trunkline

Viperdet Trunkline

Global

Updated: January 21, 2024
Equipment
Non-Electric
Initiation
Surface, Underground

Product Description

Viperdet Trunkline assemblies consist of a specific length of shock tube with a low shrapnel millisecond delay detonator crimped to the one end and closed at the other end by means of an ultrasonic seal. The low shrapnel surface detonator is contained in a colour coded connector and a colour coded label marked with the specified delay is attached to the shock tube within 10cm of the seal.

Application

Viperdet Trunkline non-electric detonators are used to make connections with Viperdet non-electric products.
Viperdet Trunkline non-electric detonators are used in surface and underground mines, quarries, and construction blasting.
Viperdet Trunkline non-electric detonators must not be used in flammable environments such as methane or coal dust.
Viperdet Trunkline non-electric detonators are safe against extraneous electric currents except lightning.

Product Specifications

Detonator strength: No. 3 Detonator.
Shock tube: Triple extruded polyethylene exterior over surlyn inner.
Shell: Aluminium.
Shock tube strength: Resistant to abrasion and cutting under normal handling conditions.
Nominal VOD of shock tube: 2000 m/s.
Connector: Color-coded to identify respective delay timings.

Guidelines for Use

Priming and Initiation

Viperdet Trunkline can be used to sequentially delay and initiate Viperdet MS Downlines.
Maximum number of shock tubes inserted into a Viperdet Trunkline connector is six (6).
Never insert detonating cord into a Viperdet Trunkline connector.
To prevent a snap, slap, and shoot incident (unexpected detonation) never pull or stretch non-electric shock tube to the point of breaking.

Handling and Storage
Minimum storage temperature (- 45°C) and maximum storage temperature (+65°C). The product should be stored in its original packaging.

Shelf Life
Viperdet MS Downline shelf life is 36 months when stored in original packaging, under dry conditions and moderate temperature, and in a ventilated and approved magazine.

Disposal
Disposal of expired non-electric detonators and its packaging should conducted of by authorized personnel and/or companies.

Delay Times

Delay time (ms)Connector colour
17Yellow
25Red
42White
67Black

Packaging

Units are placed in plastic inner packaging that is heat-sealed and packed in boxes.

Other lengths are available on request.

Length (m)Units/box
4.2260
6250

 

UN Classification for Transportation and Storage

Proper shipping name
Detonator assemblies, non-electric.

Class
1

Division
1.1 B (UN 0360).
1.4 B (UN 0361).
1.4 B (UN 0500).

Safe Use

  • Never fight explosive fires.
  • Refer to Safety Data Sheet (SDS) for first aid information.
  • All explosives must be transported and stored in accordance to relevant regulations.
  • All explosives are classified as dangerous goods and may cause damage to property, personal harm, or death, if not used correctly.
  • Always keep products away from sources of heat, sparks, flame or hot surfaces and avoid mixing with combustibles or incompatible materials.

In case of emergencies, click here to contact our team for assistance.

Disclaimer

All rights reserved. To the maximum extent permitted by law.

Omnia disclaims all liability whatsoever, whether arising in contract, delict (including negligence) or otherwise in relation to the use of any products/solutions or services and all implied warranties, terms and conditions relating to the products/solutions or services (whether implied by statue, common law or otherwise), including (without limitation) any warranty, term or condition as to accuracy, completeness, satisfactory quality, performance, fitness for purpose or any special purpose, non-infringement, information accuracy, as between Omnia and you, are hereby excluded. Omnia specifically disclaims liability and will not be responsible for, any liability or damages, howsoever arising, resulting from the use or reliance upon the information in this document.

You assume sole responsibility for results obtained from the use of the products/solutions or services, and for conclusions drawn from such use.

© Omnia Group (Pty) Ltd

Table of Contents
    Add a header to begin generating the table of contents
    Scroll to Top

    Brand

    Viper

    BME Main Branch
    South Africa

    Omnia Holdings, Building H:
    Monte Circle Business Park
    178 Montecasino Boulevard,
    Fourways, Sandton, 2191

    +27 11 709 8765
    admin@bmeapp.co.za

    Simple Subscription Form (#12)

    © 2021 OMNIA Group. All rights reserved.

    Web Design by Teracore