A member of the Omnia Group

Viperdet SCX

Viperdet SCX

Canada, USA

Updated: June 9, 2023
Equipment
Non-Electric
Initiation
Trunkline
Surface, Underground

Product Description

Viperdet SCX non-electric detonators permit blast sequencing by introducing intervals of delay times in between blast holes through the use of easy surface connections. Viperdet SCX non-electric detonator assemblies consist of a specific length of yellow shock tube, a low strength low shrapnel detonator, and a surface connector that can hold between one and six shock tubes. 

Application

The Viperdet SCX offers greater versatility in the timing design of any blast when used together with Viperdet MS, Viperdet LP or Viperdet Dual. The plastic, color-coded connector can accept six shock tubes.

Viperdet SCX non-electric detonators must not be used in flammable environments such as methane or coal dust. 

Viperdet non-electric detonators are safe against extraneous electric currents except lightning.

Features

Detonator strength: Low strength, low shrapnel surface delay detonator

Shock tube: The yellow coloured shock tube is resistant to abrasion and designed to elongate to avoid tensile strength damage under normal use conditions. Shock tube coiled in "Figure 80"' configuration for ease of deployment and avoids tangles.

Label tag: Water resistant. Laser printing provides clear and smudge resistant timing and product information.

Connector: Plastic, anti-slip grip designed to initiate up to six shock tubes. Colour-coded blocks are used to distinguish different delay periods.

Guidelines for Use

Priming and Initiation

Viperdet SCX must never be used to initiate detonating cord such as trunklines for pre-splits.

To prevent a snap, slap, and shoot incident (unexpected detonation) never pull or stretch non-electric shock tube to the point of breaking.

Ground Temperature

This product may be used in ground temperatures up to a maximum of 65°C (150°F). If the application requires use outside of this temperature range please contact a BME Technical Representative for additional guidance.

Handling and Storage

All explosives must be transported and stored in accordance with relevant local, state and federal regulations.

Viperdet SCX shelf life is 36 months when stored in the original packaging, under dry conditions and moderate temperate, and in a well ventilated and approved magazine.

Product Specifications

Delay Times:

Surface Time (ms)

Column 1Column 2
Connector ColourTime (ms)
Brown0
Green9
Yellow17
Red25
Lime Green33
White42
Black67
Blue100
Purple150
Orange200
Pink300

Packaging

1.1B Classification

Column 1Column 2Column 3Column 4Column 5Column 6
Length (m)Length (ft)Units/caseGross Weight (kg)Gross Weight (lb)
3.6122101226.5
4.8161801124.2
6201801328.7
9301201124.2
12401201326.5

Standard Packaging, Class 1.1B:

Case dimensions (L × W × H): 470 mm × 444 mm × 265 mm (18.5 in × 17.5 in × 9.4 in).

Product Risk Profile

All explosives are classified as dangerous goods and may cause damage to property, personal harm, or death, if not used correctly.

Severe detonation hazard when exposed to heat.
Detonation may occur from impact, friction, or excessive heating.
Never attempt to fight explosives fires.

First Aid: Refer to Safety Data Sheet for first-aid information.

UN Classification for Transportation and Storage

All explosives must be transported in accordance with relevant local, state and federal regulations

Transportation Classification: Detonator Assemblies, Non-Electric, Class and Division 1.1B, PG II, UN 0360.

Safe Use

  • Never fight explosive fires.
  • Refer to Safety Data Sheet (SDS) for first aid information.
  • All explosives must be transported and stored in accordance to relevant regulations.
  • All explosives are classified as dangerous goods and may cause damage to property, personal harm, or death, if not used correctly.
  • Always keep products away from sources of heat, sparks, flame or hot surfaces and avoid mixing with combustibles or incompatible materials.

In case of emergencies, click here to contact our team for assistance.

Disclaimer

All rights reserved. To the maximum extent permitted by law.

Omnia disclaims all liability whatsoever, whether arising in contract, delict (including negligence) or otherwise in relation to the use of any products/solutions or services and all implied warranties, terms and conditions relating to the products/solutions or services (whether implied by statue, common law or otherwise), including (without limitation) any warranty, term or condition as to accuracy, completeness, satisfactory quality, performance, fitness for purpose or any special purpose, non-infringement, information accuracy, as between Omnia and you, are hereby excluded. Omnia specifically disclaims liability and will not be responsible for, any liability or damages, howsoever arising, resulting from the use or reliance upon the information in this document.

You assume sole responsibility for results obtained from the use of the products/solutions or services, and for conclusions drawn from such use.

© Omnia Group (Pty) Ltd

Table of Contents
    Add a header to begin generating the table of contents
    Scroll to Top

    Brand

    BME
    Viper

    BME Main Branch
    South Africa

    Omnia Holdings, Building H:
    Monte Circle Business Park
    178 Montecasino Boulevard,
    Fourways, Sandton, 2191

    +27 11 709 8765
    admin@bmeapp.co.za

    Simple Subscription Form (#12)

    © 2021 OMNIA Group. All rights reserved.

    Web Design by Teracore