A member of the Omnia Group

Viperdet LP

Viperdet LP

Global

Updated: January 21, 2024
Equipment
LP, Non-Electric
Initiation
LP
Construction, Mining, Quarrying
Underground

Product Description

Viperdet LP is a non-electric long-period delay detonator. Viperdet LP assemblies are precise and reliable. Units consist of a specific length of yellow shock tube with a high-strength delay detonator crimped to the one end and a seal at the other end. A detonating cord connector clip is attached to the sealed end.

Application

Viperdet LP non-electric detonators are designed for use in underground mining and tunnelling.

Viperdet LP non-electric detonators must not be used in flammable environments such as methane or coal dust.

Viperdet non-electric detonators are safe against extraneous electric currents except lightning.

 

Features

Detonator Strength: No. 8 detonator with a double crimp.

Shock Tube: Yellow, with three layers coiled in a 'Figure 80' for ease of deployment and the avoidance of tangles. The shock tube is resistant to abrasion and designed to elongate to avoid tensile strength damage under normal use conditions.

J-Hook: J-hook to ease connection to detonating cord (5 g/m minimum core load).

Label tag: Water resistant. Laser printing provides clear and smudge resistant timing and product information.

Guidelines for Use

Priming and Initiation

Viperdet LP non-electric detonators can be initiated by a single strand of detonating cord with a minimum core load of 5 g/m.

Viperdet LP non-electric detonators can be used to prime the full range of BME's detonator sensitive explosive products.

To prevent a snap, slap, and shoot incident (unexpected detonation) never pull or stretch non-electric shock tube to the point of breaking.

Ground Temperature

This product may be used in ground temperatures up to a maximum of 65°C (150°F). If the application requires use outside of this temperature range please contact a BME Technical Representative for additional guidance.

Sleep Time

The recommended maximum sleep time is 21 days. If the application requires longer in-hole sleep time, please consult with a BME Technical Representative for guidance.

Handling and Storage

All explosives must be transported and stored in accordance with relevant local, state and federal regulations.

Viperdet LP shelf life is 36 months when stored in the original packaging, under dry conditions at moderate temperatures, and in a well ventilated and approved magazine.

Packaging

Standard lengths below. Other lengths upon request.

1.1B Classification

Column 1Column 2Column 3Column 4Column 5
Length (m)Length (ft)Units/caseCase weight (kg)Case weight (lb)
4.8162401226
6201801022
7.8261501022

 

Unit packaging is in coils.

Delay Time

Column 1Column 2
DelayTime (ms)
1100
2200
3300
4400
5500
6600
7700
8800
9900
101000
121200
141400
161600
181800
202000
252500
303000
353500
404000
454500
505000
555500
606000
707000
808000
909000

Product Risk Profile

All explosives are classified as dangerous goods and may cause damage to property, personal harm, or death, if not used correctly.

Severe detonation hazard when exposed to heat.
Detonation may occur from impact, friction, or excessive heating.
Never attempt to fight explosives fires.

First Aid: Refer to Safety Data Sheet for first-aid information.

UN Classification for Transportation and Storage

Class 1.1B, UN 0360, DETONATOR ASSEMBLIES, NON-ELECTRIC
Class 1.4B, UN 0361, DETONATOR ASSEMBLIES, NON-ELECTRIC
Class 1.4S, UN 0500, DETONATOR ASSEMBLIES, NON-ELECTRIC

Safe Use

  • Never fight explosive fires.
  • Refer to Safety Data Sheet (SDS) for first aid information.
  • All explosives must be transported and stored in accordance to relevant regulations.
  • All explosives are classified as dangerous goods and may cause damage to property, personal harm, or death, if not used correctly.
  • Always keep products away from sources of heat, sparks, flame or hot surfaces and avoid mixing with combustibles or incompatible materials.

In case of emergencies, click here to contact our team for assistance.

Disclaimer

All rights reserved. To the maximum extent permitted by law.

Omnia disclaims all liability whatsoever, whether arising in contract, delict (including negligence) or otherwise in relation to the use of any products/solutions or services and all implied warranties, terms and conditions relating to the products/solutions or services (whether implied by statue, common law or otherwise), including (without limitation) any warranty, term or condition as to accuracy, completeness, satisfactory quality, performance, fitness for purpose or any special purpose, non-infringement, information accuracy, as between Omnia and you, are hereby excluded. Omnia specifically disclaims liability and will not be responsible for, any liability or damages, howsoever arising, resulting from the use or reliance upon the information in this document.

You assume sole responsibility for results obtained from the use of the products/solutions or services, and for conclusions drawn from such use.

© Omnia Group (Pty) Ltd

Table of Contents
    Add a header to begin generating the table of contents
    Scroll to Top

    Brand

    BME
    Viper

    BME Main Branch
    South Africa

    Omnia Holdings, Building H:
    Monte Circle Business Park
    178 Montecasino Boulevard,
    Fourways, Sandton, 2191

    +27 11 709 8765
    admin@bmeapp.co.za

    Simple Subscription Form (#12)

    © 2021 OMNIA Group. All rights reserved.

    Web Design by Teracore