Product Description

Cast Viper Boosters are a molecular explosive composition of RDX and TNT enclosed in a high visibility cylindrical shell. A PETN capsule is positioned internally near the detonator well to ensure reliable initiation when using 3.6 g/m (18 grain/ft) detonating cord or stronger. As a primer assembly Viper Boosters develop high detonation pressure and high detonation velocity to initiate primary explosive loads.

Viper Boosters

Application

Viper Boosters are designed to be used in conjunction with a high strength initiator to make up primer assemblies. Primers made with Viper Boosters are widely used to initiate non-detonator sensitive bulk and packaged explosives and blasting agents. Viper Boosters provide reliable initiation for blasting in surface mines, underground mines, quarries, and civil construction.

Primary Benefits

Reliable initiation of primary explosive loads by primers made with standard high strength electronic and non-electric detonators.

Reliable initiation of primary explosive loads by primers made with 3.6 g/m (18 grain/foot) detonating cord or stronger.

Viper Boosters are smooth and clean with both ends covered. This minimizes high explosive dust in the cases and exposure of personnel to high explosive dust.

Consistent smooth and straight detonator well and detonating cord tunnel with no distortion or blockage. This minimizes the risk of personnel forcing initiation devices into the booster during primer assembly.

Guidelines for Use

Use with Detonating Cord

Always consult with a BME Technical Representative for guidance before using a detonating cord as an initiator for this product.

Ground Temperature

This product may be used in ground temperatures to a maximum of 70°C. If the application requires use outside of this temperature range please contact a BME Technical Representative for additional guidance.

Reactive Ground

Reactive ground is typically characterised by the presence of sulphide mineralization. If the application requires use in known reactive ground, or in untested sulphide bearing ground, please contact a BME Technical Representative for additional guidance.

Sleep Time

The recommended maximum sleep time is 21 days. Sleep time is dependent on factors such as hole diameter, density, ground water conditions and initiation system. If the application requires longer in-hole sleep time, please consult with a BME Technical Representative for guidance.

Handling and Storage

Viper Boosters must be handled and stored with care. Viper Boosters are made with molecular high explosives that can be initiated by intense friction, impact, static (lightning), or heat.

All explosives must be transported and stored in accordance with relevant regulations. 

Store Viper Boosters in a dry and well ventilated magazine.

Packaging

Column 1Column 2Column 3Column 4Column 5
Viper Booster 150Viper Booster 400Viper Booster 800Unit
Unit Weight150400800g
Units per Case903516per case
Net Weight per Case13.51412.8kg
Diameter365478mm
Length125125120mm

Velocity of Detonation = 8 550 m/s
Detonation Pressure = 14.85 GPa
Density = 1.80 g/cm³
Water Resistance = Excellent

UN Classification for Transportation and Storage

All explosives must be transported and stored in accordance with relevant regulations.

Authorised Name: Viper Booster
Correct Shipping Name: Booster, Without Detonator 
Classification: 1.1D
UN Number: 0042

Authorised Name: Viper Booster
Correct Shipping Name: Booster, without Detonator 
Classification: 1.1D
UN Number: 0042

Safe Use

  • Never fight explosive fires.
  • Refer to Safety Data Sheet (SDS) for first aid information.
  • All explosives must be transported and stored in accordance to relevant regulations.
  • All explosives are classified as dangerous goods and may cause damage to property, personal harm, or death, if not used correctly.
  • Always keep products away from sources of heat, sparks, flame or hot surfaces and avoid mixing with combustibles or incompatible materials.

In case of emergencies, click here to contact our team for assistance.

Disclaimer

All rights reserved. To the maximum extent permitted by law.

Omnia disclaims all liability whatsoever, whether arising in contract, delict (including negligence) or otherwise in relation to the use of any products/solutions or services and all implied warranties, terms and conditions relating to the products/solutions or services (whether implied by statue, common law or otherwise), including (without limitation) any warranty, term or condition as to accuracy, completeness, satisfactory quality, performance, fitness for purpose or any special purpose, non-infringement, information accuracy, as between Omnia and you, are hereby excluded. Omnia specifically disclaims liability and will not be responsible for, any liability or damages, howsoever arising, resulting from the use or reliance upon the information in this document.

You assume sole responsibility for results obtained from the use of the products/solutions or services, and for conclusions drawn from such use.

© Omnia Group (Pty) Ltd

Table of Contents
    Add a header to begin generating the table of contents
    Scroll to Top

    Brand

    BME
    Viper

    BME Main Branch
    South Africa

    Omnia Holdings, Building H:
    Monte Circle Business Park
    178 Montecasino Boulevard,
    Fourways, Sandton, 2191

    +27 11 709 8765
    admin@bmeapp.co.za

    Simple Subscription Form (#12)

    © 2021 OMNIA Group. All rights reserved.

    Web Design by Teracore