The AXXIS Titanium Loggers are Robust, Hand-held devices that allow Logging and testing of Detonators. The Mobile devices are Manufactured by Trimble and have an AXXIS developed CAP which docks onto the device. The CAP contains the Detonator Communication Circuit, and this makes possible the Logging and Programming of Detonators. It can Read/Write to the Detonators Non-volatile memory, test a single Detonator, test multiple Detonators and transfer the Logged blast files to Blaster.
Column 1 | Column 2 |
---|---|
Logging Device Type | Robust Trimble Handheld Device |
Operating system | Android 10 |
Colour | Yellow and Black |
Screen Size and Resolution | 15.24 cm (6 inches): 1920 x 1080 pixels, high resolution |
User Interface | Colour Touch Screen, Function Buttons, Rain Mode |
Battery | Lithum-ion |
Battery Capacity | 3.7V8000mAh29.6Whr |
POD Maximum Output | 9 volts, 70 mA |
Logger Mass | 0.61 kg |
Maximum Detonators per Log Line | 500 detonators |
Maximum Detonators per Log File | 20 000 detonators per file |
Intruder Detection | 500 connected |
Calibration Intervals | 2 years |
Logger Functions | Scanning UID’s, Programming Firing Times, Programming to Detonator NVM, Centralized Programming, 1-500 Detonators Connected, Testing 1-500 Detonators Connected |
Detonator Communication | Via Attached CAP, Communication 1-500 Detonators Connected.Read Functionality, Program Functionality, Test Functionality |
Blasting Box Communication | Bluetooth, Wired, QR Code Authentication |
Testing Functions | Detonator Program Status, Detonator Program Details, Detonator Temperature, Line Current Consumption Leakage Test, Line Test for Connected, Line Test for Missing, Line Test for Intruders |
Resistance to Electrostatic Discharge | Electrical Fast Transient, Burst Immunity (±2kV) |
Electrostatic Discharge Immunity Test (±8kV contact, ±15kV air), Electrical Fast Transient/Burst Immunity (±2kV) | |
Operating Temperature | -20 °C to +55 °C |
Storage Temperature | -40 °C to +70 °C |
The AXXIS Titanium Loggers are easy and convenient to use. They operate on the Android operating system, which facilitates the upload of history files, current logging activity, reporting applications and web pages.
In order to configure the Blaster at Fire time, a Key Logger is required. This operates with a one-time pin, the pin is generated and managed by the Software. As a security measure, any Blaster that has not been configured for the Blast and bound through the one-time pin on the Key Logger will not function for that Blast. The Key Logger and the one-time pin are required at the Blast Controller for the system to be Armed.
Upon Blast completion, all Loggers and Blasters return to a neutral un-configured state. Files are stored in memory and can be archived by the User.
Operation: -20 °C to +55 °C, Storage: -40 °C to +70 °C
Water/Dust Ingress: IP65 and IP68 (IEC 60529)
Drop Shock Protection: IEC 60068-2-32:1975: 122cm
In case of emergencies, click here to contact our team for assistance.
Omnia disclaims all liability whatsoever, whether arising in contract, delict (including negligence) or otherwise in relation to the use of any products/solutions or services and all implied warranties, terms and conditions relating to the products/solutions or services (whether implied by statue, common law or otherwise), including (without limitation) any warranty, term or condition as to accuracy, completeness, satisfactory quality, performance, fitness for purpose or any special purpose, non-infringement, information accuracy, as between Omnia and you, are hereby excluded. Omnia specifically disclaims liability and will not be responsible for, any liability or damages, howsoever arising, resulting from the use or reliance upon the information in this document.