A member of the Omnia Group

TDC 600 Logger

TDC 600 Logger

AXXIS | Titanium | TDC 600

Global

Updated: August 27, 2023
Technology
EBS, Electric Initiation
EBS, Electronic
Initiation
Portable
Construction, Mining, Quarrying
Surface, Underground

Product Description

The AXXIS Titanium Loggers are Robust, Hand-held devices that allow Logging and testing of Detonators. The Mobile devices are Manufactured by Trimble and have an AXXIS developed CAP which docks onto the device. The CAP contains the Detonator Communication Circuit, and this makes possible the Logging and Programming of Detonators. It can Read/Write to the Detonators Non-volatile memory, test a single Detonator, test multiple Detonators and transfer the Logged blast files to Blaster.

Technical Properties

Column 1Column 2
Logging Device TypeRobust Trimble Handheld Device
Operating systemAndroid 10
ColourYellow and Black
Screen Size and Resolution15.24 cm (6 inches): 1920 x 1080 pixels, high resolution
User InterfaceColour Touch Screen, Function Buttons, Rain Mode
Battery Lithum-ion
Battery Capacity 3.7V 8000mAh 29.6Whr
POD Maximum Output9 volts, 70 mA
Logger Mass0.61 kg
Maximum Detonators per Log Line500 detonators
Maximum Detonators per Log File20 000 detonators per file
Intruder Detection500 connected
Calibration Intervals2 years
Logger FunctionsScanning UID’s, Programming Firing Times, Programming to Detonator NVM, Centralized Programming, 1-500 Detonators Connected, Testing 1-500 Detonators Connected
Detonator CommunicationVia Attached CAP, Communication 1-500 Detonators Connected.Read Functionality, Program Functionality, Test Functionality
Blasting Box CommunicationBluetooth, Wired, QR Code Authentication
Testing FunctionsDetonator Program Status, Detonator Program Details, Detonator Temperature, Line Current Consumption Leakage Test, Line Test for Connected, Line Test for Missing, Line Test for Intruders
Resistance to Electrostatic DischargeElectrical Fast Transient, Burst Immunity (±2kV)
Electrostatic Discharge Immunity Test (±8kV contact, ±15kV air), Electrical Fast Transient/Burst Immunity (±2kV)
Operating Temperature-20 °C to +55 °C
Storage Temperature-40 °C to +70 °C

Guidelines for Use

System Usage

The AXXIS Titanium Loggers are easy and convenient to use.  They operate on the Android operating system, which facilitates the upload of history files, current logging activity, reporting applications and web pages.

In order to configure the Blaster at Fire time, a Key Logger is required. This operates with a one-time pin, the pin is generated and managed by the Software.  As a security measure, any Blaster that has not been configured for the Blast and bound through the one-time pin on the Key Logger will not function for that Blast. The Key Logger and the one-time pin are required at the Blast Controller for the system to be Armed.

Upon Blast completion, all Loggers and Blasters return to a neutral un-configured state. Files are stored in memory and can be archived by the User.

Operating Temperature

Operation: -20 °C to +55 °C, Storage: -40 °C to +70 °C

Water, Dust, and Drop Shock Resistance

Water/Dust Ingress: IP65 and IP68 (IEC 60529)

Drop Shock Protection: IEC 60068-2-32:1975: 122cm

Safe Use

  • Never fight explosive fires.
  • Refer to Safety Data Sheet (SDS) for first aid information.
  • All explosives must be transported and stored in accordance to relevant regulations.
  • All explosives are classified as dangerous goods and may cause damage to property, personal harm, or death, if not used correctly.
  • Always keep products away from sources of heat, sparks, flame or hot surfaces and avoid mixing with combustibles or incompatible materials.

In case of emergencies, click here to contact our team for assistance.

Disclaimer

All rights reserved. To the maximum extent permitted by law.

Omnia disclaims all liability whatsoever, whether arising in contract, delict (including negligence) or otherwise in relation to the use of any products/solutions or services and all implied warranties, terms and conditions relating to the products/solutions or services (whether implied by statue, common law or otherwise), including (without limitation) any warranty, term or condition as to accuracy, completeness, satisfactory quality, performance, fitness for purpose or any special purpose, non-infringement, information accuracy, as between Omnia and you, are hereby excluded. Omnia specifically disclaims liability and will not be responsible for, any liability or damages, howsoever arising, resulting from the use or reliance upon the information in this document.

You assume sole responsibility for results obtained from the use of the products/solutions or services, and for conclusions drawn from such use.

© Omnia Group (Pty) Ltd

Table of Contents
    Add a header to begin generating the table of contents
    Scroll to Top

    Brand

    AXXIS
    Titanium
    Related Products

    Android
    Titanium Range

    BME Main Branch
    South Africa

    Omnia Holdings, Building H:
    Monte Circle Business Park
    178 Montecasino Boulevard,
    Fourways, Sandton, 2191

    +27 11 709 8765
    admin@bmeapp.co.za

    Simple Subscription Form (#12)

    © 2021 OMNIA Group. All rights reserved.

    Web Design by Teracore