Product Description

Innovex Uphole is a bulk pumped booster-sensitive gassed emulsion. Innovex Uphole is a dual salt emulsion formulated with refined oils.

Application

Innovex Uphole is designed for general blasting applications in underground mines, quarries, and construction with wet or dry holes. Innovex Uphole is not for use in the presence of sulphide reactive ground or elevated ground temperatures.

Primary Benefits

Innovex Uphole may be loaded at varying densities to achieve energies that optimize fragmentation distribution and minimise perimeter overbreak. The Innovex Uphole dual salt formulation is a product demonstrated to generate very low levels of post blast fume.

Technical Properties

Column 1Column 2Column 3Column 4Column 5Column 6Column 7
PropertyUnitBase EmulsionGas Sensitized EmulsionGas Sensitized EmulsionGas Sensitized EmulsionGas Sensitized Emulsion
Densityg/cm³1.47 to 1.510.901.001.151.20
Velocity of Detonationm/sec4112449650755275
Relative Weight StrengthRWS67738491
Relative Bulk StrengthRBS7592121136

Velocity of Detonation, Relative Weight and Bulk Strengths calculated using the IPX code at a density of 1.20 g/cm³ and a cut-off pressure of 100 MPa relative to ANFO at a density of 0.80 g/cm³.

Actual in field velocity of detonation will vary and is dependent on hole diameter and confinement.

Guidelines for Use

Priming and Initiation

Column 1Column 2
Hole DiameterMinimum Cast Booster Mass
Innovex Lateral holes 32 mm to 48 mm12 g or larger
Innovex Uphole holes greater than 89 mm90 g or larger

Innovex Uphole is compatible with most non-electric and electronic detonator systems.

Use of detonating cord with Innovex Uphole may influence blast outcomes.

Blasthole Charge Length, Hole Diameter and Density Relationships

Maximum hole depth depends on product selection, hole diameter, product densities, critical void space and the presence of water. Please contact a BME Technical Representative for additional guidance and site specific calculations using BME’s DensDepth program.

Ground Temperature

This product may be used in ground temperatures from 0° to a maximum of 65°C. If the application requires use outside of this temperature range please contact a BME Technical Representative for additional guidance.

Reactive Ground

This product is not formulated for use in reactive ground. Reactive ground is typically characterised by the presence of sulphide mineralization. If the application requires use in known reactive ground, or in untested sulphide bearing ground, please contact a BME Technical Representative for additional guidance.

Sleep Time

The recommended maximum sleep time is 21 days. Sleep time is dependent on factors such as hole diameter, density, ground water conditions and initiation system. If the application requires longer in-hole sleep time, please consult with a BME Technical Representative for guidance.

UN Classification for Transportation and Storage

Product Classification of System Components
Authorised Name: INNOVEX UPHOLE - Base Emulsion
Correct Shipping Name: AMMONIUM NITRATE EMULSION
Classification: 1.5D
UN Number: 0332

Authorised Name: INNOVEX Sensitizing Agent
Correct Shipping Name: NITRITES, ORGANIC, AQUEOUS SOLUTION, N.O.S.
Classification: 5.1
UN Number: 3219

Product Classification of Finished Sensitized Explosive Product
Authorised Name: INNOVEX UPHOLE
Correct Shipping Name: EXPLOSIVE, BLASTING
Classification: 1.1D
UN Number: 0241

Safe Use

  • Never fight explosive fires.
  • Refer to Safety Data Sheet (SDS) for first aid information.
  • All explosives must be transported and stored in accordance to relevant regulations.
  • All explosives are classified as dangerous goods and may cause damage to property, personal harm, or death, if not used correctly.
  • Always keep products away from sources of heat, sparks, flame or hot surfaces and avoid mixing with combustibles or incompatible materials.

In case of emergencies, click here to contact our team for assistance.

Disclaimer

All rights reserved. To the maximum extent permitted by law.

Omnia disclaims all liability whatsoever, whether arising in contract, delict (including negligence) or otherwise in relation to the use of any products/solutions or services and all implied warranties, terms and conditions relating to the products/solutions or services (whether implied by statue, common law or otherwise), including (without limitation) any warranty, term or condition as to accuracy, completeness, satisfactory quality, performance, fitness for purpose or any special purpose, non-infringement, information accuracy, as between Omnia and you, are hereby excluded. Omnia specifically disclaims liability and will not be responsible for, any liability or damages, howsoever arising, resulting from the use or reliance upon the information in this document.

You assume sole responsibility for results obtained from the use of the products/solutions or services, and for conclusions drawn from such use.

© Omnia Group (Pty) Ltd

Table of Contents
    Add a header to begin generating the table of contents
    Scroll to Top

    Brand

    BME
    Innovex
    Related Products

    Innovex UG

    BME Main Branch
    South Africa

    Omnia Holdings, Building H:
    Monte Circle Business Park
    178 Montecasino Boulevard,
    Fourways, Sandton, 2191

    +27 11 709 8765
    admin@bmeapp.co.za

    Simple Subscription Form (#12)

    © 2021 OMNIA Group. All rights reserved.

    Web Design by Teracore