Innovex 60 is a bulk, fuel rich, base emulsion for preparing a booster sensitive, gassed emulsion blend containing 40% un-oiled AN prills (Innovex 206). Innovex 60 is a dual salt emulsion formulated with reprocessed oil and alternative fuels.
Innovex 60 is designed for making a 60% emulsion/40% AN prill booster sensitive gassed emulsion blend (Innovex 206) for blasting applications in open pit mines, quarries, and construction with dry holes to damp holes. Innovex 60 should not be used as a straight emulsion. It is not for use in the presence of unprotected sulphide reactive ground or in elevated ground temperatures. Also refer to Innovex 206 TDS.
Innovex emulsion blends may be loaded at varying densities to achieve energies that optimize fragmentation distribution and influence mine to mill productivity. The Innovex dual salt emulsion formulations are products demonstrated to generate very low levels of post blast NOx fume. The use of reprocessed oil in the fuel phase can contribute towards sustainability goals.
Column 1 | Column 2 | Column 3 |
---|---|---|
Property | Base Emulsion | |
Density | g/cm³ | 1.46 to 1.50 |
Column 1 | Column 2 |
---|---|
Hole Diameter | Min Cast Booster Mass |
Greater than 127 mm | 400 g |
Innovex 60 is compatible with most non-electric and electronic detonator systems.
Use of detonating cord with Innovex 60 may influence blast outcomes.
Maximum hole depth depends on product selection, hole diameter, product densities, critical void space and the presence of water. Please contact a BME Technical Representative for additional guidance and site specific calculations using BME’s DensDepth program.
This product may be used in ground temperatures from 0° to a maximum of 70°C. If the application requires use outside of this temperature range please contact a BME Technical Representative for additional guidance.
This product is not formulated for use in reactive ground. Reactive ground is typically characterised by the presence of sulphide mineralization. If the application requires use in known reactive ground, or in untested sulphide bearing ground, please contact a BME Technical Representative for additional guidance.
The recommended maximum sleep time is 21 days. Sleep time is dependent on factors such as hole diameter, density, ground water conditions and initiation system. If the application requires longer in-hole sleep time, please consult with a BME Technical Representative for guidance.
The storage life for Innovex 60 is typically up to 6 months under good storage conditions. Please consult with a BME Technical Representative for site specific storage life guidance.
Product Classification of System Components
Authorised Name: Innovex 60 – Base Emulsion
Correct Shipping Name: AMMONIUM NITRATE EMULSION
Classification: 5.1
UN Number: 3375
Authorised Name: Innovex Sensitizing Agent
Correct Shipping Name: NITRITES, ORGANIC, AQUEOUS SOLUTION, N.O.S.
Classification: 5.1
UN Number: 3219
Authorised Name: Porous Granular Ammonium Nitrate
Correct Shipping Name: AMMONIUM NITRATE
Classification: 5.1
UN Number: 1942
Product Classification of Finished Sensitized Explosive Product
Authorised Name: Innovex 206
Correct Shipping Name: EXPLOSIVE, BLASTING
Classification: 1.1D
UN Number: 0241
In case of emergencies, click here to contact our team for assistance.
Omnia disclaims all liability whatsoever, whether arising in contract, delict (including negligence) or otherwise in relation to the use of any products/solutions or services and all implied warranties, terms and conditions relating to the products/solutions or services (whether implied by statue, common law or otherwise), including (without limitation) any warranty, term or condition as to accuracy, completeness, satisfactory quality, performance, fitness for purpose or any special purpose, non-infringement, information accuracy, as between Omnia and you, are hereby excluded. Omnia specifically disclaims liability and will not be responsible for, any liability or damages, howsoever arising, resulting from the use or reliance upon the information in this document.
You assume sole responsibility for results obtained from the use of the products/solutions or services, and for conclusions drawn from such use.
© Omnia Group (Pty) Ltd