A member of the Omnia Group

Viperdet SD

Viperdet SD

Global, Canada, SADC, South Africa, USA, West Africa, Zambia

Updated: August 27, 2023
Equipment
Minimize Shrapnel Damage
Non-Electric
Initiation
Construction, Mining, Quarrying
Surface, Underground

Product Description

Viperdet Dual SD is a non-electric detonator comprised of a specific length of green shock tube with a high-strength in-hole delay detonator on one end and a low-base charge surface delay detonator in a connector block on the other end. The unit is designed to ensure easy connection and reliable initiation, while minimizing shrapnel damage to exposed shock tube. 

Application

Viperdet SD non-electric detonators are designed to provide reliable sequential initiation of explosives charges in underground narrow reef stoping applications.

Viperdet Dual non-electric detonators must not be used in flammable environments such as methane or coal dust.

Viperdet non-electric detonators are safe against extraneous electric currents except lightning.

Features

Detonator strengths: High strength No. 8 in-hole detonator. Low strength No. 3 surface detonator.

Delay timing: In-hole detonator = 3800ms. Surface detonator = 200ms.

Shock tube: Extruded polyethylene exterior over surlyn inner with minimum of 19 kg (41 lb) tensile strength.

Connector: T-clip ratchet connector. The connector can hold up to 4 shock tubes and is designed to ensure reliable initiation, while minimising shrapnel damage to the shock tube.

Guidelines for Use

Priming and Initiation

Viperdet Dual SD non-electric detonators can be used to prime the full range of BME's detonator sensitive explosive products.

To prevent a snap, slap, and shoot incident (unexpected detonation) never pull or stretch non-electric shock tube to the point of breaking.

Ground Temperature

This product may be used in ground temperatures up to a maximum of 65°C (150°F). If the application requires use outside of this temperature range please contact a BME Technical Representative for additional guidance.

Sleep Time

The recommended maximum sleep time is 21 days. If the application requires longer in-hole sleep time, please consult with a BME Technical Representative for guidance.

Handling and Storage

All explosives must be transported and stored in accordance with relevant local, state and federal regulations.

Viperdet Dual SD shelf life is 36 months when stored in the original packaging, under dry conditions and moderate temperate, and in a well ventilated and approved magazine.

Product Specifications

Column 1Column 2
LengthUnits/box
2.1 m400
2.4 m350
3.0 m350
3.6 m300
4.2 m250
4.8 m250

Packaging

Units are placed in plastic inner packaging that is heat sealed and packed in boxes.
Other lengths are available on request.

Product Risk Profile

All explosives are classified as dangerous goods and may cause damage to property, personal harm, or death, if not used correctly.

Severe detonation hazard when exposed to heat.
Detonation may occur from impact, friction, or excessive heating.
Never attempt to fight explosives fires.

First Aid: Refer to Safety Data Sheet for first-aid information.

 

UN Classification for Transportation and Storage

Class 1.1B, UN No. 0360, DETONATOR ASSEMBLIES, NON-ELECTRIC.
Class 1.4B, UN No. 0361, DETONATOR ASSEMBLIES, NON-ELECTRIC.
Class 1.4S, UN No. 0500, DETONATOR ASSEMBLIES, NON-ELECTRIC.

Safe Use

  • Never fight explosive fires.
  • Refer to Safety Data Sheet (SDS) for first aid information.
  • All explosives must be transported and stored in accordance to relevant regulations.
  • All explosives are classified as dangerous goods and may cause damage to property, personal harm, or death, if not used correctly.
  • Always keep products away from sources of heat, sparks, flame or hot surfaces and avoid mixing with combustibles or incompatible materials.

In case of emergencies, click here to contact our team for assistance.

Disclaimer

All rights reserved. To the maximum extent permitted by law.

Omnia disclaims all liability whatsoever, whether arising in contract, delict (including negligence) or otherwise in relation to the use of any products/solutions or services and all implied warranties, terms and conditions relating to the products/solutions or services (whether implied by statue, common law or otherwise), including (without limitation) any warranty, term or condition as to accuracy, completeness, satisfactory quality, performance, fitness for purpose or any special purpose, non-infringement, information accuracy, as between Omnia and you, are hereby excluded. Omnia specifically disclaims liability and will not be responsible for, any liability or damages, howsoever arising, resulting from the use or reliance upon the information in this document.

You assume sole responsibility for results obtained from the use of the products/solutions or services, and for conclusions drawn from such use.

© Omnia Group (Pty) Ltd

Table of Contents
    Add a header to begin generating the table of contents
    Scroll to Top

    Brand

    BME
    Viper

    BME Main Branch
    South Africa

    Omnia Holdings, Building H:
    Monte Circle Business Park
    178 Montecasino Boulevard,
    Fourways, Sandton, 2191

    +27 11 709 8765
    admin@bmeapp.co.za

    Simple Subscription Form (#12)

    © 2021 OMNIA Group. All rights reserved.

    Web Design by Teracore